Biasi RinNova 30S System Boiler & Vertical Flue - Natural Gas / LPG - 30kW

Biasi RinNova 30S System Boiler & Vertical Flue - Natural Gas / LPG - 30kW

  • Lead Time: 1-2 Working Days*
Regular price £659.43
Regular price Sale price £659.43
Sale Sold out
Shipping calculated at checkout.

Boiler with Vertical Flue Kit

Available as Boiler Only or with Horizontal Flue as a pack

Biasi RinNova Adaptive System User Manual

  • 7 Year Warranty
  • ProFit Warranty - 8 Years
 RinNova Adaptive 30S
Nominal heating d.h.w. heat input kW 26,0/31,0
Minimum heat input for heating/d.h.w kW 3,8/3,8
Maximum useful heating/sanitary power 60°/80°C *  kW 25,6/30,6
Minimum useful heating/heating power 60°/80°C * kW 3,6/3,6
Maximum useful heating/sanitary power 30°/50°C ** kW 28,3/33,7
Minimum useful heating/sanitary power 30°/50°C ** kW 4,0/4,0
Quantity of condensate at Q.nom. 30°/50°C (in heating mode) **
5
Quantity of condensate at Q.nom. 30°/50°C (in heating mode) **
0,6
Condensate pH
4,0
Nom. efficiency 60°/80°C * % 98,6
Min. efficiency 60°/80°C *   % 94,5
Nom. efficiency 30°/50°C ** % 108,7
Min. efficiency 30°/50°C **  % 105,8
Efficiency at 30 % load ** % 109,7
Energy efficiency ηs  % 94
Thermal losses at the chimney with burner in operation Pf (%) 1,2
Thermal losses at the chimney with off turned burner ΔT 50°C 
0,2
Thermal losses to the environment through the casing with the burner in operation with the burner in operation Pd (%) 0,2
NOx Class 6
Weighted NOx [Hs] *** mg/kWh 34
Minimum/maximum heating temperature ****  °C 25/80
Minimum/maximum heating pressure bar 0,3/3
Available heating head (at 1000 l/h)  mbar 320
Expansion tank capacity (total/useful) l 7
Minimum/maximum d.h.w temperature °C 35/55
Minimum/maximum d.h.w pressure bar 0,3/10
Maximum flow rate (Δt = 25 K) / (Δt = 35 K) l/min 18,3/12,8
Specific d.h.w flow (Δt = 30 K) *****  l/min 15,2
Voltage / electric power at nominal heat input V~/ W 230/96
Electric power at minimum heat input W 11
Electric power in stand-by  W 3
Electric degree of protection IPX5D
Minimum/maximum flue gas temperature# °C 44/78
Minimum/Maximum flue gas mass flow rate # kg/s 0,0044/0,0144
Minimum/maximum air mass flow rate # kg/s 0,0044/0,0139
Max. length of coaxial smoke outlet (Ø 60/100 mm / Ø 80/125 mm) m 10/12
Max length of split flue exhaust (Ø 80+80 mm)
40
Height x Width x Depth mm 700 x 400 x 300
Weight kg 36
Water content of the boiler l 2,0


* With return water temperatures that do not allow condensation.
** With return water temperatures that allow condensation.
*** With coaxial flue outlet 60/100 L 0.9 m and METHANE G20 gas.
**** At minimum useful power.
***** Referred to EN 625 standard.
# Values referred to tests with 80 mm 1 + 1 split flue and methane gas G20.

 