Skip to product information
1 of 1

Baxi 818 System 2 with MagnaClean Micro2 Filter - System Boiler - 7814313

Baxi 818 System 2 with MagnaClean Micro2 Filter - System Boiler - 7814313

  • Lead Time: In stock, ready for next day delivery*
Regular price £989.47
Regular price Sale price £989.47
Sale Sold out
Shipping calculated at checkout.

Baxi 800 System 2

The Baxi 800 System 2 boiler has a 10-year parts and labour warranty* and can be installed with a hot water cylinder, such as the Baxi cylinder or Megaflo Eco.

It is the perfect solution for homes that need lots of hot water or have more than one bathroom.

Baxi 800 System 2 User Guide Baxi 800 System 2 with External Pressure Gauge User Guide Baxi 800 System 2 Installation & Service Manual Baxi 800 System 2 with External Pressure Gauge Installation & Service Manual

Warranty

10-year parts and labour warranty†

Filter included

Comes with an Adey Micro2 magnetic system filter to protect your heating system and boiler*

Smart thermostat

Compatible with Baxi uSense smart thermostat, which you can control using an app on your phone

Ready for winter

Pre-heated condensate trap to help prevent freezing in winter – less risk of frozen condensate pipes!

Fuel types

Works with natural gas or LPG, without a conversion kit

Pressure gauge

External analogue pressure gauge for easy self-top up, reducing the need for engineer call outs

Baxi 800 System 2 Boiler Dimensions

Dimensions

  • A: Boiler width = 395mm
  • B: Boiler height = 700mm
  • C: Boiler depth = 285mm
  • D: Side clearance = 2.5mm
  • E: Upper clearance = 178mm
  • F: Lower clearance = 150mm
  • G: Front clearance = 5mm in operation (450mm for servicing)
    • Technical Specification

      Product model 18 System 24 System 30 System
      Product code 7814313 7814314 7814315
      Gas
      Natural Gas or LPG Yes Yes Yes
      Inlet supply pressure (natural gas) mbar(nominal) 20 20 20
      Maximum gas rate (G20) Qmax (m3/hr) 1.97 2.61 3.26
      Heat input CHkW (max) gross (QnHs) 18.6 24.7 30.9
      Heat input CHkW (min) gross (QnHs) 4.9 4.9 6
      Heat output CH (non-condensing) - kW (max) (Pn) 18 24 30
      Heat output CH (non-condensing) - kW (min) (Pn) 4.8 4.8 5.8
      Heat output CH (condensing) - kW (max) (Pnc) 19.9 26.3 32.4
      Heat output CH (condensing) - kW (min) (Pnc) 5.2 5.2 6.4
      Heat input domestic hot water (DHW) - kW (max) gross (QnwHs) n/a n/a n/a
      Heat input domestic hot water (DHW) - kW (max) n/a n/a n/a
      Water heating efficiency class A A A
      Electrical
      Permanent live required Yes Yes Yes
      Pump overrun Yes Yes Yes
      Integral 'boiler only' frost thermostat Yes Yes Yes
      Hydraulic
      Maximum DHW flow rate (Delta T @ 35c rise) (I/min) n/a n/a n/a
      Minimum DHW flow rate required (I/min) 2 2 2
      Minimum operating DHW pressure required (bar) 0.5 0.5 0.5
      Integral expansion vessel (litres) 7 7 7
      Maximum capacity of CH system (litres) 100 100 100
      Weights
      Installer lift weight (boiler) (kg) 29 30 30
View full details

Save more with Kings Rewards!

That's right! On top of our already competitive prices, you could save even more with our trade exclusive rewards program Kings Rewards. To find out more, hit the button below!