Baxi 600 Heat

Heat only boilers are also known as regular, conventional, traditional or open vent boilers.

Baxi 600 Heat User Guide Baxi 600 Heat Installation & Service Manual

Warranty

7-year parts and labour warranty for peace of mind†

Compact size

Lightweight and compact cupboard fit

Neater finish

Rear flue option for an even neater finish

Compatible

Compatible with market-leading Megaflo Eco cylinder

Baxi 600 Heat only Boiler Dimensions

Dimensions

  • A: Boiler width = 370mm
  • B: Boiler height = 625mm
  • C: Boiler depth = 270mm
  • D: Side clearance = 5mm
  • E: Upper clearance = 190mm*, 35mm* if using rear flue
  • F: Lower clearance = 120mm*, 35mm in 300mm deep wall cupboard
  • G: Front clearance = 5mm in operation (500mm for servicing)
    • Technical Specification

      Product Model 16 Heat 19 Heat 25 Heat
      Product Code 7711999 7712020 7712022
      Controls and accessories
      Operating mode selector switch with reset (Yes/No) Yes Yes Yes
      User adjustable CH temperature (Range - e.g. 45° to 82°) Yes Yes Yes
      LED temp/status/fault diagnosis display (Yes/No) Yes Yes Yes
      Baxi twin channel wired programmer - 7212443 Optional Optional Optional
      Baxi room thermostat - 720971601 Optional Optional Optional
      Gas
      Boiler Plus ErP (%) 93 93 93
      SAP 2009 annual efficiency (PCDB/SEDBUK) % 89.2 89.2 89.1
      NOx class 6 6 6
      ErP Product Information
      NOx (mg/kWh) 20 21 24
      Sound Power Level, Indoors (LWA dB) 39 41 45
      Space Heating Efficiency Class A A A
      Heat Input CH - kW max gross (QnHs) 18.32 21.75 28.62
      Heat Input CH - kW min gross (QnHs) 8.59 8.59 8.59
      Heat Output CH (non condensing) - kW (Pn) 16 19 25
      Heat Output CH (non condensing) - kW (Pn) 7.5 7.5 7.5
      Gas supply connection (mm) 22 22 22
      Inlet supply pressure (natural gas) - mbar 20 20 20
      Maximum gas rate (m3/hr) 1.75 2.07 2.73
      Mechanical and hydraulic
      Compartment ventilation required (Yes/No) No No No
      Flow / return pipe size (mm) 22 22 22
      Condensate discharge pipe size (mm) 21.5 21.5 21.5
      Electrical
      Electrical supply - Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz
      Permanent live required (Yes/No) No No No
      Switched live (Yes/No) Yes Yes Yes
      Electrical power cable fitted as standard (1m of 3 core) Yes Yes Yes
      Power consumption (Watts) 20 23 33
      External fuse rating (Amps) 3 3 3
      Internal fuse rating 1.6T 1.6T 1.6T
      Boiler IP rating (electrical protection) - Approval category IPX4D IPX4D IPX4D
      Pump overrun (Yes/No) No No No
      Concentric flue system
      Standard telescopic concentric flue (Length in mm) 315-500 315-500 315-500
      Horizontal and Vertical concentric (60/100 mm) - Max equivalent length (m) 6 6 6
      Horizontal and Vertical concentric (60/100 mm) - Reduction per 135° bend (m) 0.5 0.5 0.5
      Horizontal and Vertical concentric (60/100 mm) - Reduction per 93° bend (m) 1 1 1
      Weights
      Installer lift weight (boiler) - Max (kg) 17.4 17.4 17.4
      Gross packaged boiler weight (kg) 19.5 19.5 19.5