{"title":"Inta Heat Pump Anti-Freeze Protection","description":"","products":[{"product_id":"inta-anti-freeze-valve-guard-zeroguard","title":"Inta Zero Anti-Freeze Valve Guard - ZEROGUARD","description":"\u003cp\u003eInta Zero Anti-Freeze Valve Guard\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787199298\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787199298\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Default Title","offer_id":51778083356939,"sku":"INT00000540","price":7.46,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00000550_80b383e3-a384-45d2-bace-b2107cfccc23.png?v=1787199479"},{"product_id":"inta-bond-and-seal-290mm-insulbond","title":"Inta Primary Pro Bond and Seal - 290ml - INSULBOND","description":"\u003cp\u003ePrimary Pro 290ml Bond And Seal\u003c\/p\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"290ml","offer_id":51778086469899,"sku":"INT00000780","price":12.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00000780_8927b54c-ac9c-4782-b1b5-a4a0a1da137f.png?v=1787201640"},{"product_id":"inta-insulation-for-1-1-4-zero-swivel-anti-freeze-valve-insulzero35sw","title":"Inta Insulation for Zero Swivel Anti-Freeze Valve - Suitable for 35mm \u0026 1 1\/4\" - INSULZERO35SW","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Inta Zero’s thermostatic element sits directly in the system’s water flow, allowing it to accurately react to the temperature of the system, regardless of ambient temperature. This means the Inta Zero can be fully insulated to help maintain the COP and SCOP of your system without affecting the operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\r\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\r\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\r\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\r\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Default Title","offer_id":51778129592587,"sku":"INT00004100","price":5.4,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00004100.png?v=1787313258"},{"product_id":"inta-insulation-for-1-zero-swivel-anti-freeze-valve-insulzero28sw","title":"Inta Insulation for Zero Swivel Anti-Freeze Valve - Suitable for 28mm \u0026 1\" - INSULZERO28SW","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Inta Zero’s thermostatic element sits directly in the system’s water flow, allowing it to accurately react to the temperature of the system, regardless of ambient temperature. This means the Inta Zero can be fully insulated to help maintain the COP and SCOP of your system without affecting the operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\r\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\r\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\r\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\r\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Default Title","offer_id":51778129658123,"sku":"INT00004110","price":3.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00004100.png?v=1787313258"},{"product_id":"inta-zero-anti-freeze-professional-installer-pack-1-1-4-male-afcompack114","title":"Inta Zero Anti-Freeze Professional Installer Pack - 1 1\/4\" Male - AFCOMPACK114","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\" Male","offer_id":51778210955531,"sku":"INT00008350","price":214.52,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"},{"product_id":"inta-zero-anti-freeze-professional-installer-pack-1-male-afcompack1","title":"Inta Zero Anti-Freeze Professional Installer Pack - 1\" Male - AFCOMPACK1","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"1\" Male","offer_id":51778211184907,"sku":"INT00008360","price":195.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"},{"product_id":"inta-zero-anti-freeze-professional-installer-pack-28mm-afcompack","title":"Inta Zero Anti-Freeze Professional Installer Pack - 28mm - AFCOMPACK","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"28mm","offer_id":51778211250443,"sku":"INT00008370","price":195.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"},{"product_id":"inta-zero-anti-freeze-professional-installer-pack-35mm-afcompack35","title":"Inta Zero Anti-Freeze Professional Installer Pack - 35mm - AFCOMPACK35","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"35mm","offer_id":51778211283211,"sku":"INT00008380","price":214.52,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"},{"product_id":"inta-zero-anti-freeze-valve-1-1-4-male-zero114","title":"Inta Zero Anti-Freeze Valve - 1 1\/4\" Male - ZERO114","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\" Male","offer_id":51778211348747,"sku":"INT00008390","price":93.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-1-1-4-male-x-1-1-4-female-swivel-zero14sw","title":"Inta Zero Anti-Freeze Valve - 1 1\/4\" Male x 1 1\/4\" Female Swivel - ZERO14SW","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\" x 1 1\/4\" Female Swivel","offer_id":51778211381515,"sku":"INT00008400","price":110.82,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-1-male-zero001","title":"Inta Zero Anti-Freeze Valve - 1\" Male - ZERO001","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1\" Male","offer_id":51778211414283,"sku":"INT00008410","price":86.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-1-male-x-1-female-swivel-zero1sw","title":"Inta Zero Anti-Freeze Valve - 1\" Male x 1\" Female Swivel - ZERO1SW","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1\" Male x 1\" Female Swivel","offer_id":51778211447051,"sku":"INT00008420","price":103.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-28mm-zero28","title":"Inta Zero Anti-Freeze Valve - 28mm - ZERO28","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"28mm","offer_id":51778211479819,"sku":"INT00008430","price":86.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-35mm-zero35","title":"Inta Zero Anti-Freeze Valve - 35mm - ZERO35","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"35mm","offer_id":51778211512587,"sku":"INT00008440","price":96.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008390.png?v=1787390048"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-1-1-4-male-zero114zg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 1 1\/4\" Male - ZERO114ZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\" Male","offer_id":51778211578123,"sku":"INT00008450","price":100.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-1-1-4-male-x-1-1-4-female-swivel-zero114swzg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 1 1\/4\" Male x 1 1\/4\" Female Swivel - ZERO114SWZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\" Male x 1 1\/4\" Female Swivel","offer_id":51778211643659,"sku":"INT00008460","price":117.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-1-male-zero001zg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 1\" Male - ZERO001ZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1\" Male","offer_id":51778211676427,"sku":"INT00008470","price":93.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-1-male-x-1-female-swivel-zero1swzg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 1\" Male x 1\" Female Swivel - ZERO1SWZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"1\" Male x 1\" Female Swivel","offer_id":51778211938571,"sku":"INT00008480","price":110.39,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-28mm-zero28zg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 28mm - ZERO28ZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"28mm","offer_id":51778212102411,"sku":"INT00008490","price":93.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-anti-freeze-valve-with-zero-guard-35mm-zero35zg","title":"Inta Zero Anti-Freeze Valve with Zero Guard - 35mm - ZERO35ZG","description":"\u003cp\u003eThe patent pending Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate. A protective ring has been included in the construction to prevent system debris from clogging the operation of the valve. Double o-rings alse reduce surface friction on the operating member to ensure correct operation and reliability even after years of non-movement.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55336\/?tmstv=1787389926\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/55339\/?tmstv=1787389926\" target=\"_blank\" title=\"Installation \u0026amp; Operation Manual\" rel=\"noopener\"\u003eInstallation \u0026amp; Operating Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to quickly and accurately react to the water temperature in the heat pump circuit and does not need the influence of the ambient temperature to operate\u003c\/li\u003e\n\u003cli\u003eA protective ring has been included in the construction to prevent system debris from clogging the operation of the valve\u003c\/li\u003e\n\u003cli\u003eDouble O-rings and reduced surface friction treatment on the operating member also ensure correct operation and reliability even after years of non-movement\u003c\/li\u003e\n\u003cli\u003eBuilding Regulations Part L\u003c\/li\u003e\n\u003cli\u003eR290 Refrigerant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kings Plumbing Supplies","offers":[{"title":"35mm","offer_id":51778212331787,"sku":"INT00008500","price":103.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008450.png?v=1787391650"},{"product_id":"inta-zero-swivel-anti-freeze-professional-installer-pack-1-1-4-afcompacksw35","title":"Inta Zero Swivel Anti-Freeze Professional Installer Pack - 1 1\/4\" - AFCOMPACKSW35","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"1 1\/4\"","offer_id":51778212626699,"sku":"INT00008510","price":216.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"},{"product_id":"inta-zero-swivel-anti-freeze-professional-installer-pack-1-afcompacksw","title":"Inta Zero Swivel Anti-Freeze Professional Installer Pack - 1\" - AFCOMPACKSW","description":"\u003cp\u003eThe patented Inta Zero Anti-Freeze Valves have been specifically designed to quickly and accurately react to the water temperature in the heat pump circuit and do not need the influence of the ambient temperature to operate.\u003c\/p\u003e\n\u003cp\u003eBuilding regulations Part L states that all external fittings on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency. Inta Zero Anti-Freeze Valves will still maintain correct operation and discharge the water at the same temperature even when a system is correctly insulated.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.intatec.co.uk\/download\/33624\/?tmstv=1787388222\" target=\"_blank\" title=\"Datasheet\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eThe Inta Zero Anti-Freeze valves have been Independently tested using a controlled Ambient Temperature between -1°C to 1°C and starting water temperature 10°C to demonstrate the possibility of insulating the Inta Zero Valve without affecting the performance:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWithout Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.49°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 1 hour 4mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWith Insulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWater Discharge Temperature = 2.03°C\u003c\/li\u003e\n\u003cli\u003eTime taken to begin discharge = 4hour 3mins\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the Inta Zero valves are insulated, then due care must be taken to ensure that all external pipework and fittings are fully and appropriately insulatedand sealed. Failure to do so could prevent the proper operation of the Zero valve resulting in colder areas of a system being damaged by freezing. The Anti-vacuum valve must be kept clear at all times, Intatec recommend using the ZEROGUARD anti-vacuum cover (inspected on annual service).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2x Zero Anti-Freeze Valves\u003c\/li\u003e\n\u003cli\u003e2x Zero Valve Insulation Jackets\u003c\/li\u003e\n\u003cli\u003e2x Zero Guard Anti-Freeze Protectors\u003c\/li\u003e\n\u003cli\u003e1x Tube of Condensate Pro Bond \u0026amp; Seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Freeze Valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Inlet Pressure (Static): 10 Bar\u003c\/li\u003e\n\u003cli\u003eWorking Temperature Range: 0 to 80°C\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature Range: -30 to 60°C\u003c\/li\u003e\n\u003cli\u003eOpening Temperature: 3°C\u003c\/li\u003e\n\u003cli\u003eClosing Temperature: 4°C\u003c\/li\u003e\n\u003cli\u003eSensitivity: ±1°C\u003c\/li\u003e\n\u003cli\u003eMedium: Water\u003c\/li\u003e\n\u003cli\u003eMax Discharge Flow Rate @ 3 Bar: 1.5 L\/H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWall thickness: 19mm +0 \/ -3mm\u003c\/li\u003e\n\u003cli\u003eMaterial: treated closed cell polyethylene\u003c\/li\u003e\n\u003cli\u003eTemperature range: -45°C to 105°C\u003c\/li\u003e\n\u003cli\u003eThermal conductivity: λ = 0.034 W\/mk at 0°C\u003c\/li\u003e\n\u003cli\u003eWater vapour diffusion resistance: μ ≥ 39,300\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"1\"","offer_id":51778212987147,"sku":"INT00008520","price":197.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/INT00008350.png?v=1787389547"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/collections\/INT00008450-INT00008500_4190a0f6-0c1d-4cd4-9899-0cd00e8e31ee.png?v=1750850673","url":"https:\/\/plumblikeaking.co.uk\/collections\/inta-heat-pump-anti-freeze-protection.oembed?page=2","provider":"Kings Plumbing Supplies Limited","version":"1.0","type":"link"}