{"title":"Baxi 800 Combi 2 Boilers","description":"","products":[{"product_id":"baxi-824-combi-2-with-magnaclean-micro2-filter-combi-boiler-7814304","title":"Baxi 824 Combi 2 with MagnaClean Micro2 Filter - Combi Boiler - 7814304","description":"\u003cp\u003e\u003cstrong\u003eBaxi 800 Combi 2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufactured in the UK, the Baxi 800 Combi 2 has a 10-year parts and labour warranty†.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt fits neatly in a standard kitchen cupboard or anywhere else in the home as it works so quietly! It’s compatible with the Baxi uSense smart control, so you can operate it wherever you are, using your phone or tablet.\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/Quick-start-guide_2.pdf?v=1770578941\" title=\"Baxi 800 Combi 2 User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-user-guide.pdf?v=1770578940\" title=\"Baxi 800 Combi 2 with External Pressure Gauge User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-installation-service-manual.pdf?v=1770578944\" title=\"Baxi 800 Combi 2 Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-b-basic-combi-installation-manuals_1.pdf?v=1770578945\" title=\"Baxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10-year parts and labour warranty†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFilter included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eComes with an Adey Micro2 magnetic system filter to protect your heating system and boiler*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy top up\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEasyFill makes it easy to top up the central heating system pressure without having to call an engineer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReady for winter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePre-heated condensate trap to help prevent freezing in winter – less risk of frozen condensate pipes!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWorks with natural gas or LPG, without a conversion kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure gauge\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal analogue pressure gauge for easy self-top up, reducing the need for engineer call outs\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/edge.sitecorecloud.io\/bdrthermea1-platform-production-864a\/media\/Project\/BaxiUK\/BaxiUK\/Images\/Homeowner\/Products\/Boilers\/baxi-b-basic-dimensions.jpg?h=1280\u0026amp;iar=0\u0026amp;w=1280\" alt=\"Baxi 800 Combi 2 Boiler Dimensions\" width=\"367\" height=\"367\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Boiler width = 395mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB:\u003c\/strong\u003e Boiler height = 700mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e Boiler depth = 285mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD:\u003c\/strong\u003e Side clearance = 2.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE:\u003c\/strong\u003e Upper clearance = 178mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF:\u003c\/strong\u003e Lower clearance = 200mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG:\u003c\/strong\u003e Front clearance = 5mm in operation (450mm for servicing)\u003c\/li\u003e\n\u003cul\u003e\n\u003cdiv class=\"title-container w-full flex gap-2 flex-col\"\u003e\n\u003ch2\u003eTechnical Specification\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-outer w-full overflow-x-scroll\"\u003e\n\u003cdiv class=\"table-container w-full\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Model\u003c\/th\u003e\n\u003cth\u003e824 Combi 2\u003c\/th\u003e\n\u003cth\u003e830 Combi 2\u003c\/th\u003e\n\u003cth\u003e836 Combi 2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814304\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814305\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814306\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eGas\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural gas or LPG\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet supply pressure (natural gas) (mbar (nominal))\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Gas Rate (G20) Qmax (m3\/hr)\u003c\/td\u003e\n\u003ctd\u003e2.61\u003c\/td\u003e\n\u003ctd\u003e3.26\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat input CH\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (max) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e20.6\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (min) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (non-condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pn)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pn)\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e21.8\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Input Domestic Hot Water (DHW) - kW max gross (QnwHs)\u003c\/td\u003e\n\u003ctd\u003e27.4\u003c\/td\u003e\n\u003ctd\u003e30.9\u003c\/td\u003e\n\u003ctd\u003e36.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Output Domestic Hot Water (DHW) - kW max\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Heating Efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent Live Required\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal fuse rating (Amps)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Overrun\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral 'boiler only' Frost Thermostat\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHydraulic\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DHW flow rate (Delta T @ 35'C rise) (l\/min)\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum DHW flow rate required (l\/min)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating DHW pressure required (bar)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Expansion Vessel -Size (litres)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacity of CH System (litres)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Automatic Bypass\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeights\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstaller Lift Weight (boiler) (kg)\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Combi \/ Natural Gas or LPG \/ 24kW","offer_id":52886962635019,"sku":"BAX00005140","price":1036.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/BAX00005140_e41e04cc-18b5-4a2e-b074-680e057fe643.png?v=1770636735"},{"product_id":"baxi-830-combi-2-with-magnaclean-micro2-filter-combi-boiler-7814305","title":"Baxi 830 Combi 2 with MagnaClean Micro2 Filter - Combi Boiler - 7814305","description":"\u003cp\u003e\u003cstrong\u003eBaxi 800 Combi 2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufactured in the UK, the Baxi 800 Combi 2 has a 10-year parts and labour warranty†.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt fits neatly in a standard kitchen cupboard or anywhere else in the home as it works so quietly! It’s compatible with the Baxi uSense smart control, so you can operate it wherever you are, using your phone or tablet.\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/Quick-start-guide_2.pdf?v=1770578941\" title=\"Baxi 800 Combi 2 User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-user-guide.pdf?v=1770578940\" title=\"Baxi 800 Combi 2 with External Pressure Gauge User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-installation-service-manual.pdf?v=1770578944\" title=\"Baxi 800 Combi 2 Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-b-basic-combi-installation-manuals_1.pdf?v=1770578945\" title=\"Baxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10-year parts and labour warranty†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFilter included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eComes with an Adey Micro2 magnetic system filter to protect your heating system and boiler*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy top up\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEasyFill makes it easy to top up the central heating system pressure without having to call an engineer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReady for winter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePre-heated condensate trap to help prevent freezing in winter – less risk of frozen condensate pipes!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWorks with natural gas or LPG, without a conversion kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure gauge\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal analogue pressure gauge for easy self-top up, reducing the need for engineer call outs\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/edge.sitecorecloud.io\/bdrthermea1-platform-production-864a\/media\/Project\/BaxiUK\/BaxiUK\/Images\/Homeowner\/Products\/Boilers\/baxi-b-basic-dimensions.jpg?h=1280\u0026amp;iar=0\u0026amp;w=1280\" alt=\"Baxi 800 Combi 2 Boiler Dimensions\" width=\"367\" height=\"367\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Boiler width = 395mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB:\u003c\/strong\u003e Boiler height = 700mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e Boiler depth = 285mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD:\u003c\/strong\u003e Side clearance = 2.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE:\u003c\/strong\u003e Upper clearance = 178mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF:\u003c\/strong\u003e Lower clearance = 200mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG:\u003c\/strong\u003e Front clearance = 5mm in operation (450mm for servicing)\u003c\/li\u003e\n\u003cul\u003e\n\u003cdiv class=\"title-container w-full flex gap-2 flex-col\"\u003e\n\u003ch2\u003eTechnical Specification\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-outer w-full overflow-x-scroll\"\u003e\n\u003cdiv class=\"table-container w-full\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Model\u003c\/th\u003e\n\u003cth\u003e824 Combi 2\u003c\/th\u003e\n\u003cth\u003e830 Combi 2\u003c\/th\u003e\n\u003cth\u003e836 Combi 2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814304\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814305\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814306\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eGas\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural gas or LPG\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet supply pressure (natural gas) (mbar (nominal))\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Gas Rate (G20) Qmax (m3\/hr)\u003c\/td\u003e\n\u003ctd\u003e2.61\u003c\/td\u003e\n\u003ctd\u003e3.26\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat input CH\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (max) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e20.6\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (min) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (non-condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pn)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pn)\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e21.8\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Input Domestic Hot Water (DHW) - kW max gross (QnwHs)\u003c\/td\u003e\n\u003ctd\u003e27.4\u003c\/td\u003e\n\u003ctd\u003e30.9\u003c\/td\u003e\n\u003ctd\u003e36.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Output Domestic Hot Water (DHW) - kW max\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Heating Efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent Live Required\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal fuse rating (Amps)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Overrun\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral 'boiler only' Frost Thermostat\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHydraulic\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DHW flow rate (Delta T @ 35'C rise) (l\/min)\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum DHW flow rate required (l\/min)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating DHW pressure required (bar)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Expansion Vessel -Size (litres)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacity of CH System (litres)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Automatic Bypass\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeights\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstaller Lift Weight (boiler) (kg)\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Combi \/ Natural Gas or LPG \/ 30kW","offer_id":52886962864395,"sku":"BAX00005170","price":1165.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/BAX00005170_bc335618-105c-45cc-9e39-0981cd07c8f5.png?v=1770636739"},{"product_id":"baxi-836-combi-2-with-magnaclean-micro2-filter-combi-boiler-7814306","title":"Baxi 836 Combi 2 with MagnaClean Micro2 Filter - Combi Boiler - 7814306","description":"\u003cp\u003e\u003cstrong\u003eBaxi 800 Combi 2\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufactured in the UK, the Baxi 800 Combi 2 has a 10-year parts and labour warranty†.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt fits neatly in a standard kitchen cupboard or anywhere else in the home as it works so quietly! It’s compatible with the Baxi uSense smart control, so you can operate it wherever you are, using your phone or tablet.\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/Quick-start-guide_2.pdf?v=1770578941\" title=\"Baxi 800 Combi 2 User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-user-guide.pdf?v=1770578940\" title=\"Baxi 800 Combi 2 with External Pressure Gauge User Guide\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge User Guide\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-800-combi-2-installation-service-manual.pdf?v=1770578944\" title=\"Baxi 800 Combi 2 Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/baxi-b-basic-combi-installation-manuals_1.pdf?v=1770578945\" title=\"Baxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\" rel=\"noopener\" target=\"_blank\"\u003eBaxi 800 Combi 2 with External Pressure Gauge Installation \u0026amp; Service Manual\u003c\/a\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e10-year parts and labour warranty†\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFilter included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eComes with an Adey Micro2 magnetic system filter to protect your heating system and boiler*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy top up\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEasyFill makes it easy to top up the central heating system pressure without having to call an engineer\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReady for winter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePre-heated condensate trap to help prevent freezing in winter – less risk of frozen condensate pipes!\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFuel types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWorks with natural gas or LPG, without a conversion kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure gauge\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal analogue pressure gauge for easy self-top up, reducing the need for engineer call outs\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/edge.sitecorecloud.io\/bdrthermea1-platform-production-864a\/media\/Project\/BaxiUK\/BaxiUK\/Images\/Homeowner\/Products\/Boilers\/baxi-b-basic-dimensions.jpg?h=1280\u0026amp;iar=0\u0026amp;w=1280\" alt=\"Baxi 800 Combi 2 Boiler Dimensions\" width=\"367\" height=\"367\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e Boiler width = 395mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB:\u003c\/strong\u003e Boiler height = 700mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e Boiler depth = 285mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD:\u003c\/strong\u003e Side clearance = 2.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE:\u003c\/strong\u003e Upper clearance = 178mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF:\u003c\/strong\u003e Lower clearance = 200mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG:\u003c\/strong\u003e Front clearance = 5mm in operation (450mm for servicing)\u003c\/li\u003e\n\u003cul\u003e\n\u003cdiv class=\"title-container w-full flex gap-2 flex-col\"\u003e\n\u003ch2\u003eTechnical Specification\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-outer w-full overflow-x-scroll\"\u003e\n\u003cdiv class=\"table-container w-full\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Model\u003c\/th\u003e\n\u003cth\u003e824 Combi 2\u003c\/th\u003e\n\u003cth\u003e830 Combi 2\u003c\/th\u003e\n\u003cth\u003e836 Combi 2\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814304\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814305\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e7814306\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eGas\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural gas or LPG\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet supply pressure (natural gas) (mbar (nominal))\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Gas Rate (G20) Qmax (m3\/hr)\u003c\/td\u003e\n\u003ctd\u003e2.61\u003c\/td\u003e\n\u003ctd\u003e3.26\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat input CH\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (max) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e20.6\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (min) Gross (QnHs)\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (non-condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pn)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pn)\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHeat Output CH (condensing)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Max) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e21.8\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003ctd\u003e27.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekW (Min) (Pnc)\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Input Domestic Hot Water (DHW) - kW max gross (QnwHs)\u003c\/td\u003e\n\u003ctd\u003e27.4\u003c\/td\u003e\n\u003ctd\u003e30.9\u003c\/td\u003e\n\u003ctd\u003e36.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Output Domestic Hot Water (DHW) - kW max\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Heating Efficiency class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent Live Required\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal fuse rating (Amps)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Overrun\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral 'boiler only' Frost Thermostat\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHydraulic\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum DHW flow rate (Delta T @ 35'C rise) (l\/min)\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum DHW flow rate required (l\/min)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating DHW pressure required (bar)\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Expansion Vessel -Size (litres)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Capacity of CH System (litres)\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Automatic Bypass\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeights\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstaller Lift Weight (boiler) (kg)\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e29.2\u003c\/td\u003e\n\u003ctd\u003e30.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Kings Plumbing Supplies","offers":[{"title":"Combi \/ Natural Gas or LPG \/ 36kW","offer_id":52886963061003,"sku":"BAX00005200","price":1294.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/files\/BAX00005200_204e5030-7693-4985-9f97-90808a8a29b6.png?v=1770636744"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/9546\/2667\/collections\/baxi_800_boiler.png?v=1770592371","url":"https:\/\/plumblikeaking.co.uk\/collections\/baxi-800-combi-2-boilers.oembed","provider":"Kings Plumbing Supplies Limited","version":"1.0","type":"link"}